Rack Server Jakarta

R Series, Single Phase UPS, 1/ 2/ 3 kVA

The Amplon R Series is a true on-line, double-conversion UPS that protects devices from potential power problems such as spikes, surges, and brownouts. It is available in either rack or tower configuration and is recommended for servers, VoIP, telecommunications and networking.
The Amplon R Series is designed for long backup time applications with the addition of a customized battery source.
The inbuilt high level charger shortens the recharging period and increases availability.

Applications :

Rack Server Jakarta


  • Double-conversion technology provides 24/7 full-time protection
  • Automatic input frequency detection
  • Additional charger board can be added for long backup applications and reduced recharging time
  • AC-start and battery-start capabilities
  • Rail kit is included in the package
  • Rack or tower configuration in 2U size cabinet
  • Fulfill long backup time demand for mission critical applications
  • Remote management over network via software
  • High input power factor (pf > 0.97) saves installation cost
  • Input voltage range meets the needs of most applications and avoids frequent transfers to battery mode to help prolong battery life
Model   R-1K R-2K R-3K
Power Rating   1 kVA / 700 W 2 kVA / 1400 W 3 kVA / 2100 W
Input Nominal Voltage
Voltage Range
Frequency
Power Factor
220 / 230 / 240 Vac (single phase)
80 ~ 280 Vac
40 - 70 Hz
> 0.97
  Electrical Connection Power cord (IEC320 C14) Power cord (IEC320 C20) Power cord (IEC320 C20)
Output Voltage
Voltage Regulation
Frequency
Wave Form
Transient Response
Voltage Harmonic Distortion
Overload Capability
230 Vac (single phase)
± 2%
50 / 60 ±0.05 Hz
Pure sine wave
< 8%
< 3% (linear load)
105 ~ 125% : 3 minutes, 125% ~ 150% : 30 seconds, > 150% : 1 second
  Receptacle IEC320 C13 x 4 IEC320 C13 x 8
IEC320 C19 x 1
IEC320 C13 x 8
IEC320 C19 x 1
Battery & Charger Nominal Voltage
Charge Current
36 Vdc
Built-in: max 5A
Additional charger(optional)
72 Vdc
Built-in: max 4.5A
72 Vdc
Built-in: max 4.5A
Interface Standard RS232 x 1, SMART slot x 1
Conformance Safety & EMC CE, EN62040-1, EN62040-2, CISPR 22 Class A
Other Features Rail Kit
Tower Stand Kit
Data Line Protector
Included
Optional
Optional
Efficiency AC-AC > 87% (full load)
Environment Operating Temperature
Relative Humidity
0 ~ 40°C
5 ~ 95% (non-condensing)
  Audible Noise
(at one meter)
46 dBA 47 dBA 55dBA
Physical Dimensions (W x D x H)
Weight
440 x 450 x 89 mm
6.7 kg
440 x 450 x 89 mm
9.2 kg
440 x 450 x 89 mm
9.2 kg